Note: The FBB Tracker is
not needed to track these devices, with the exception of the Sailor 150, Explorer 325 and Explorer 300 when background IP/data is also needed.
Firmware versions that support tracking
- Sailor 500
- Sailor 250
- Sailor 150
- IMPORTANT FIRMWARE UPDATE: Firmware version 1.21 and higher support built in tracking. Allow multiple PDP contexts on SAILOR 150
- All firmware versions with an exception. A single PDP context is supported on Class 3 BGAN terminals, therefore, if you activate the tracking PDP context you cannot open a second context for background IP or streaming. You must disconnect the tracking PDP context first.
- Explorer 727
- Explorer 325
- IMPORTANT FIRMWARE UPDATE: Firmware version 1.21 and higher support built in tracking. Allow multiple PDP contexts on EXPLORER 325
- Firmware 1.13 and higher with an exception. A single PDP context is supported on Class 3 BGAN terminals, therefore, if you activate the tracking PDP context you cannot open a second context for background IP or streaming. You must disconnect the tracking PDP context first.
- Explorer 710
- Explorer 700
- Explorer 500
- Explorer 300
- IMPORTANT FIRMWARE UPDATE: Firmware version 3.04 and higher support built in tracking. Allow multiple PDP contexts on EXPLORER 300
- Firmware 3.03 and higher with an exception. A single PDP context is supported on Class 3 BGAN terminals, therefore, if you activate the tracking PDP context you cannot open a second context for background IP or streaming. You must disconnect the tracking PDP context first.
===
Step 1: Logging Into Your Device
IMPORTANT: You must upgrade to firmware version 1.13 or greater to support this featureLogin to http://192.168.0.01 on the same network as your Fleet Broadband
- Click on “Network User Groups”
- Enter the following: Username: admin Password: 1234
Step 2: Configure Settings
- Click on “Edit” next to “Default group”
- Change “Automatic Activation” to “Enabled”
- Click on the “Tracking” tab under “Settings” in the menu.
- Enter the follow information under “SERVER CONNECTION” For “APN”, select “SIM default”
Server IP Address | 66.165.183.84 |
Server Port | 7474 |
Client Port | 7475 |
Encryption Key | 82738287465721050827674352518283 |
- Under “POSITION REPORTS”, select the “Extended” option
- For “INTERNAL REPORT”, select “Enabled” and enter 15 minutes
- For “DISTANCE REPORT”, select “Enabled”, enter 100 for “When moved” and a time of 5 minutes is recommended for “Max one report per”